home *** CD-ROM | disk | FTP | other *** search
/ NetNews Offline 2 / NetNews Offline Volume 2.iso / news / comp / dcom / modems-part1 / 8620 < prev    next >
Encoding:
Text File  |  1996-08-05  |  1.1 KB  |  29 lines

  1. Path: mips.pfalz.de!not-for-mail
  2. From: naddy@mips.pfalz.de (Christian Weisgerber)
  3. Newsgroups: comp.dcom.modems
  4. Subject: Re: Baudrate up/down switch in V34 info wanted
  5. Date: 20 Mar 1996 16:00:12 +0100
  6. Message-ID: <4ip6hs$mg2@mips.pfalz.de>
  7. References: <1996Mar11.154956.11340@ms.philips.nl>
  8. NNTP-Posting-Host: mips.pfalz.de
  9.  
  10. tdhartog@mxsb10.ms.philips.nl (HARTOG_AW) writes:
  11.  
  12. > I am working on the datalink layer of a communications protocol over
  13. > V24/RS232 and want to have a flexible baudrate that is increased when
  14. > all data passes OK (no CRC errors) while the baudrate is descreased
  15. > when CRC occur.
  16. > The V34 protocol has a algorithm to do this and make the right decission
  17. > at the right time.
  18.  
  19. No, it hasn't. The ITU-T V.34 document specifies how to change the bit
  20. rate or the symbol rate, but the algorithm leading to such a decision is
  21. entirely up to individual manufacturers.
  22.  
  23. (The same for the V.32* family.)
  24.  
  25. -- 
  26. Christian 'naddy' Weisgerber                         naddy@mips.pfalz.de
  27.   See another pointless homepage at <URL:http://home.pages.de/~naddy/>.
  28.     -- currently reading: Philip JosΘ Farmer, The Unreasoning Mask --
  29.